Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.514
Filtrar
2.
Shanghai Kou Qiang Yi Xue ; 33(1): 90-96, 2024 Feb.
Artigo em Chinês | MEDLINE | ID: mdl-38583032

RESUMO

PURPOSE: To observe the long-term clinical effect of implants retained complete overdentures with Locator attachments. METHODS: A total of 48 patients with edentulous jaws treated with implants retained complete overdentures with Locator attachments were selected from the Outpatient Department of Peking University School and Hospital of Stomatology from 2016 to 2017. Among them, 21 patients underwent double-maxillary complete overdentures restoration and 27 patients underwent single-maxillary restoration. A total of 230 implants were implanted. The clinical observation indicators included the implant survival rate, peri-implant mucosal bleeding on probing(BOP), the change in the vertical height of alveolar bone absorption around the implants, overdenture base fracture rate, artificial tooth fall off and fracture rate and other complications. The change of the locator attachment retention force of the implant-supported overdentures was evaluated. SPSS 13.0 software package was used for data analysis. RESULTS: During the five-years clinical observation period, 5 implants fell off, 1 narrow dimeter implant in the anterior zone was broken, and 12 implants were lost to follow-up. The implant survival rate was 97.25%. One year after the restoration therapy finished, peri-implant mucosal bleeding on probing (BOP+) was detected in 48 (21.4%) implants. The average BI was 0.21±0.42, which was higher in the anterior zone than that in the posterior zone. The vertical alveolar bone absorption height around the implants was (0.21±0.35) mm, 2 implants-supported complete overdenture bases were broken. After 5 years of restoration, 163(76.89%) implants had peri-implant mucosal bleeding on probing(BOP+). The average BI was 1.00±0.70, and the vertical alveolar bone absorption height around the implants was (0.58±0.85) mm. There was no significant difference between males and females. There was no significant difference in the peri-implant mucosal bleeding index and the alveolar bone vertical absorption height between the anterior zone and the posterior zone(P>0.05). The mean BI of peri-implant mucosa and the vertical absorption height of peri-implant alveolar bone were significantly different between the 1-year observation period and the 5-year observation period respectively(P<0.01). There were 17(26.15%) cases with overdenture bases fracture, and the fracture rate of artificial teeth was 16.92%. Most of them occurred in the midline area of the anterior zone and the location of the overdenture base on the locator attachments. The average first replacement time of the locator attachment nylon retainer washer was 34.2±10.3 months. CONCLUSIONS: Implants retained complete overdentures with Locator attachments are effective in long term clinical observation. Complications are mainly found in peri-implant mucosal bleeding on probing and vertical alveolar bone absorption, and tended to increase gradually over time. The fracture of the implant retains complete overdenture bases and the fall off or fracture of the artificial teeth are the second serious complications. Overdenture base with metal frame at the location of the Locator abutment and the midline of the anterior area should be strengthened, and narrow diameter implants should be avoided as far as possible in the anterior zone.


Assuntos
Implantes Dentários , Arcada Edêntula , Masculino , Feminino , Humanos , Revestimento de Dentadura , Prótese Dentária Fixada por Implante/efeitos adversos , Retenção de Dentadura , Mandíbula/cirurgia , Implantes Dentários/efeitos adversos
3.
Trials ; 25(1): 267, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627819

RESUMO

BACKGROUND: Complete tooth loss is a significant global oral health issue, particularly impacting older individuals with lower socioeconomic status. Computer-assisted technologies enhance oral healthcare access by the elderly. Despite promising in vitro reports on digital denture materials, evidence from randomized clinical trials (RCTs) is lacking to verify their performance. This cross-over RCT will investigate whether 3D-printed implant-retained mandibular overdentures (IMO) are more satisfactory for edentulous seniors than those made through traditional methods. METHODS/DESIGN: We will recruit 26 completely edentulous participants (any sex/gender) based on the following eligibility criteria: age ≥ 60 years, no tooth extraction in the past 12 months, two implants in the lower jaw, and need for new dentures in both jaws. Each participant will receive two denture pairs, either manufactured by 3D printing or traditionally, to be worn in a random order. A timeline of 3 months with each denture pair will be considered for outcome assessment (total: 6 months). Patient satisfaction with dentures will be measured by the McGill Denture Satisfaction Questionnaire. We will evaluate other patient-reported outcomes (including oral health-related quality of life) as well as clinician-assessed quality and cost. At the end of the trial, participants will choose which denture pair they wish to keep and interviewed about their experiences with the 3D-printed IMO. The quantitative and qualitative data will be incorporated through an explanatory mixed-methods strategy. A final quantitative assessment will happen after 12 months with the preferred IMO to assess the long-term performance and maintenance needs. DISCUSSION: This mixed-methods RCT will explore patient experiences with 3D-printed IMOs, aiming to assess the potential for altering clinical practice and dental public health policies. Our results will inform policies by showing whether 3D printing offers comparable outcomes at lower costs, facilitating greater access to oral care for the elderly. TRIAL REGISTRATION: ClinicalTrials.gov, NCT06155630, Registered on 04 December 2023. https://classic. CLINICALTRIALS: gov/ct2/show/NCT06155630.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Idoso , Pessoa de Meia-Idade , Revestimento de Dentadura , Fluxo de Trabalho , Mandíbula/cirurgia , Satisfação do Paciente , Impressão Tridimensional , Prótese Dentária Fixada por Implante , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
Int J Implant Dent ; 10(1): 12, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38480586

RESUMO

PURPOSE: The aim of this article is to evaluate to the masticatory function performance and Oral Health-related Quality of Life (OHRQoL) in implant-retained overdenture compared with different implant number placements in the edentulous mandible. METHODS: From 2013 to 2015, each patients received 3 implants (iSy-Implant, Camlog, Wimsheim, Germany) in intraforaminal mandible (34, 41/31, 44). After operation, inserted implants were gradually loaded and incorporated into an overdenture with a self-aligning attachment system (Locator abutments) in 3 + 3 + 3 months. Five checked points were performed chewing cycle test with multicolored chewing gum and OHIP-G14 questionnaire and a sum score questionnaire as following: pre-operation, one implant load (41/31), two implants loaded (33,43), three implants loaded and 1-year follow up. RESULT: A total of 10 patients with 30 implants were placed, the survival rate of the implants was 100% within 1-year follow-up. Regarding the masticatory function analysis, for the higher number of chewing cycles, the higher mixing rate was observed. After 1 year, the inter-mixing rate without significant changes was found compared to the time after three implants were loaded with attachment system. The mean value of OHIP-G14 was 30.4 preoperatively, 21.1 after loading the first locator, 10.7 after loading two locator abutments, and 3.2 after loading all three locator abutments. After 1 year, OHIP-G14 was 2.6 without significantly changed. The mean of the sum score was 15.5 preoperatively, 27.8 after activation of the first locator, 39.4 after activation of two locators, 46.2 after activation of all three locators, and 47.3 after 1 year. An increase of 0.7 sum score units per time point was observed. No significance was detectable, analogous to OHIP-G14, compared to the time of activation of all three locator setups (p-value = 0.22). CONCLUSIONS: A significant improvement in masticatory function performance and OHRQoL was evaluated with the increasing number of implants with locator attachment in edentulous mandible. With the investigation of the OHIP-G14 and sum score, the results of patient report outcome might be associated with the increase in the number of implants.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Seguimentos , Estudos Prospectivos , Revestimento de Dentadura , Qualidade de Vida , Arcada Edêntula/cirurgia , Mandíbula/cirurgia
5.
BMC Oral Health ; 24(1): 405, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38555452

RESUMO

OBJECTIVE: To assess stress distribution in peri-implant bone and attachments of mandibular overdentures retained by small diameter implants, and to explore the impact of implant distribution on denture stability. METHODS: Through three-dimensional Finite Element Analysis (3D FEA), four models were established: three models of a two mandibular implants retained overdenture (IOD) and one model of a conventional complete denture (CD). The three IOD models consisted of one with two implants in the bilateral canine area, another with implants in the bilateral lateral incisor area, and the third with one implant in the canine area, and another in the lateral incisor area. Three types of loads were applied on the overdenture for each model: a 100 N vertical load and a inclined load on the left first molar, and a100N vertical load on the lower incisors. The stress distribution in the peri-implant bone, attachments, and the biomechanical behaviors of the overdentures were analyzed. RESULTS: Despite different distribution of implants, the maximum stress values in peri-implant bone remained within the physiological threshold for all models across three loading conditions. The dispersed implant distribution design (implant in the canine area) exhibited the highest maximum stress in peri-implant bone (822.8 µe) and the attachments (275 MPa) among the three IOD models. The CD model demonstrated highest peak pressure on mucosa under three loading conditions (0.8188 Mpa). The contact area between the denture and mucosa of the CD model was smaller than that in the IOD models under molar loading, yet it was larger in the CD model compared to the IOD model under anterior loading. However, the contact area between the denture and mucosa under anterior loading in all models was significantly smaller than those under molar loading. The IOD in all three models exhibited significantly less rotational movement than the complete denture. Different implant positions had minimal impact on the rotational movement of the IOD. CONCLUSION: IOD with implants in canine area exhibited the highest maximum stress in the peri-implant bone and attachments, and demonstrated increased rotational movement. The maximum principal stress was concentrated around the neck of the small diameter one-piece implant, rather than in the abutment. An overdenture retained by two implants showed better stability than a complete denture.


Assuntos
Implantes Dentários , Humanos , Revestimento de Dentadura , Análise de Elementos Finitos , Prótese Total , Mandíbula , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/métodos , Retenção de Dentadura
6.
Int J Oral Maxillofac Implants ; 39(1): 127-134, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38416006

RESUMO

PURPOSE: To evaluate the precision and efficiency of a novel guide system for single implant placement in the mandibular symphyses and to evaluate whether the outcome is affected by the level of operator experience. MATERIALS AND METHODS: A total of 90 implants were placed in three different mandibular cast types (Cawood and Howell class III, IV, and V). For each model, a complete denture was 3D printed. A polyether ether ketone rail with a guide sleeve was embedded in the middle of the denture. To determine the ideal implant position, the sleeve could be moved in a buccolingual direction. Adjustment of implant angulation was possible, and an angle correction of 0, 12, or 24 degrees was available. A total of 30 clinicians were divided into three groups: group 1 (experienced, n = 10), group 2 (beginner, n = 10), and group 3 (inexperienced, n = 10). Each clinician was asked to plan and perform a guided flapless implant placement in the mandibular symphysis. Two preoperative CBCT scans were taken; the first was to verify the planning, and the second was to adjust the planning if needed. Finally, a postoperative CBCT scan was taken to compare the planning to the final implant position. RESULTS: Based on the first CBCT, the clinicians adjusted their planning by an average of 1.66 ± 1.65 mm coronally, 2.41 ± 2.44 mm apically, and by a mean angular correction of 6.08 ± 0.77 degrees. After implant placement, the mean deviation from the planned implant position was 0.87 ± 0.58 mm at the coronal aspect and 0.98 ± 0.64 mm at the apical aspect. The mean angular deviation was 6.05 ± 0.71 degrees. Overall, there were no significant differences in coronal and apical deviation (P > .05) based on the level of experience. In terms of angulation, a significant difference was found in both planning (P = .049) and placement (P = .038) between beginners and experienced clinicians. CONCLUSIONS: Guided implant placement of a single implant in the mandibular symphysis using a removable denture with guide sleeve had an acceptable level of accuracy. Clinicians with limited experience spent more time on the procedure, resulting in less angular deviation during implant planning and placement compared to experienced clinicians.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Projetos de Pesquisa , Prótese Total , Mandíbula/cirurgia
7.
Clin Oral Investig ; 28(3): 160, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38378935

RESUMO

OBJECTIVES: Single denture rehabilitated patients have negative appraisals regarding oral function, mostly associated by stability and retention issues regarding mandibular prosthetics. Therefore, this study assessed patients' occlusal equilibration, muscle activity, and oral health-related quality of life (OHRQoL) receiving milled removable or fixed mandibular implant retained prostheses. MATERIALS AND METHODS: Twenty-two edentulous mandibular ridges patients were randomly distributed into two groups based on the definitive prosthesis received. Group I: Removable mandibular implant-supported overdenture, Group II: Implant retained fixed prosthesis. Occlusal equilibration was evaluated utilizing Occlusense, muscle activity via Electromyograph (EMG) at delivery, after one, and three months. The OHRQoL was evaluated by Oral Health Impact Profile questionnaire (OHIP-19) before delivery and after follow-ups. Data were collected, tabulated, and analyzed, utilizing independent t-test and One-way ANOVA followed Tukey`s post-hoc test. Significance level set at P ≤ 0.05. RESULTS: Groups I &II showed significant improvement in occlusal equilibration, muscle activity and OHRQoL. Group II demonstrated significantly higher improvement than group I in occlusal equilibration associated with muscle activity after 1 month, and in functional limitations domain in OHRQoL questionnaire after 3 months. CONCLUSION: Implant retained mandibular prosthesis showed improvement in occlusal equilibration, muscle activity, and OHRQoL regardless of prosthesis type employed. Fixed implant-supported prosthesis revealed better outcomes than removable mandibular implant-supported overdenture concerning occlusal equilibration, muscle activity, and OHRQoL regarding functional limitations. CLINICAL RELEVANCE: Implant retained mandibular prosthesis is one of best treatment options for single mandibular completely edentulous patients, as dental implants improved occlusal equilibration, muscle activity, and OHRQoL.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Humanos , Prótese Dentária Fixada por Implante , Revestimento de Dentadura , Mandíbula , Músculos , Ajuste Oclusal , Satisfação do Paciente , Qualidade de Vida
8.
Int J Prosthodont ; 37(1): 49-58, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381984

RESUMO

PURPOSE: To compare the biomechanical responses of a normal mandible to an osteoporotic mandible with two-implant-supported magnetic attachments. MATERIALS AND METHODS: A 3D finite-element model of a two-implant-supported mandibular overdenture with magnetic attachments was developed, and normal and osteoporotic bone samples were prepared. Four types of load were applied to the overdenture in each model: 100 N vertical and oblique loads on the right first molar, and a 100 N vertical load on the right canine and incisors. Biomechanical behaviors of the peri-implant bone, implant, and mucosa were recorded. Maximum equivalent stresses and elastic strains were analyzed. RESULTS: Equivalent elastic strain in osteoporotic cortical and cancellous bone was 9% to 71% and was 142% and 207% greater than in normal cortical bone, respectively. Equivalent elastic strain in the first molar oblique loading condition was 101% to 190% greater than in the first molar vertical loading condition. CONCLUSIONS: Osteoporotic cancellous bone was weaker and less resistant to deformation than normal bone, and oblique loading was more harmful than vertical loading.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Análise de Elementos Finitos , Análise do Estresse Dentário , Prótese Dentária Fixada por Implante , Mandíbula , Fenômenos Magnéticos , Estresse Mecânico
9.
Oral Health Prev Dent ; 22(1): 107-114, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38376434

RESUMO

PURPOSE: This study aimed to assess the impact of photodynamic therapy (PDT) on the oral health-related quality of life (OHRQoL) among denture stomatitis patients with implant overdenture prostheses (IODs). MATERIALS AND METHODS: The patients were recruited from a specialist dental practice according to selection criteria. The Candida spp. were identified and confirmed by the microbiological culture technique. Candida counts were estimated as colony-forming units (CFU/ml) at baseline, 15, 30, and 60 days. PDT was carried out twice a week with 72 h intervals for a period of 4 weeks. A structured questionnaire was used for data collection. It included the demographic details of the patients, including age, gender, education, marital and socioeconomic status (SES), oral habits, and smoking status. In addition, the Oral Health Impact Profile-EDENT (OHIP-EDENT) scale was added to assess the OHRQoL of all patients before and after PDT treatment. The data were analysed using descriptive statistics, the t-test and the Shapiro-Wilk test; statistical signifcance was set at p < 0.05. RESULTS: At baseline, the overall mean Candida CFU/ml were quite high in the implant overdenture (IODs) samples, 37.12 ± 15.8, as compared to palatal mucosa samples with 5.1 ± 2.3. After PDT treatment, a statistically significant reduction was noted in the mean Candida CFU/ml on both surfaces at all follow-up visits. It was observed that all domains of OHIP-EDENT except for physical disability and handicap showed statistically significant improvement in mean scores after PDT treatment. FL, P1, P2, D2, and D3 had statistically significant mean score improvements of 2.2, 3.1, 2.2, 1.4, and 0.7, respectively. Furthermore, after PDT treatment, the total OHIP-EDENT score showed a statistically significant improvement of 11.6. CONCLUSION: PDT treatment has a positive impact on the OHRQoL for patients with denture stomatitis. It can be used as an effective treatment option for the treatment of denture stomatitis in IOD patients.


Assuntos
Implantes Dentários , Fotoquimioterapia , Estomatite sob Prótese , Humanos , Revestimento de Dentadura , Qualidade de Vida , Estomatite sob Prótese/tratamento farmacológico
10.
J Indian Prosthodont Soc ; 24(1): 61-68, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38263559

RESUMO

AIM: The aim of this within-subject prospective clinical study was to investigate the scope of single implant mandibular overdenture by assessing its masticatory efficiency, clinical performance, and patient satisfaction compared to conventional complete dentures. SETTINGS AND DESIGN: Prospective In Vivo Study. MATERIAL AND METHODS: This prospective in vivo study was conducted in the Department of Prosthodontics and Crown and Bridge, Christian Dental College, Ludhiana. A total of 12 completely edentulous patients received a single implant in the mandibular anterior midline region. After the healing period, the conventional maxillary and mandibular dentures were fabricated. 15 days post insertion of the conventional dentures, patients were evaluated for masticatory efficiency, clinical performance including retention and stability, and patient satisfaction. To evaluate the masticatory efficiency blue raspberry and original pink "Hubba Bubba tape gum" were used as a test food. Colorimetric analysis was done to assess variance of hue. To assess clinical performance, retention, and stability of the mandibular denture was recorded using a digital force gauge and was tabulated as per CU-modified Kapur's criteria. OHIP-14 index was used to assess patient satisfaction. After evaluation of the parameters of conventional dentures, the denture was converted into an implant-retained mandibular denture by chairside conversion with locator attachments. 15 days post-implant loading, parameters of the implant retained mandibular overdenture were assessed again followed by statistical analysis. STATISTICAL ANALYSIS USED: The masticatory efficiency was assessed using a paired t-test. The patient satisfaction was sequentially assessed with Wilcoxon signed rank test and thereafter paired t-test was used to compare between conventional complete denture and overdenture. Clinical performance was assessed using the Wilcoxon signed rank test. RESULTS: The masticatory efficiency of single implant mandibular overdenture was higher than that of conventional complete dentures. The clinical performance of the overdenture was higher than that of the conventional denture. Stability being a time-dependent parameter might need longer follow-ups for further conclusions. Patient satisfaction with single implant retained overdenture was significantly higher than conventional complete dentures. CONCLUSION: Single implant mandibular overdenture has improved masticatory efficiency, clinical performance, and patient satisfaction compared to conventional complete dentures.


Assuntos
Implantes Dentários , Satisfação do Paciente , Humanos , Revestimento de Dentadura , Estudos Prospectivos , Prótese Total
11.
Oral Health Prev Dent ; 22(1): 23-30, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38223958

RESUMO

PURPOSE: To evaluate the peri-implant parameters of immediately placed and loaded mandibular overdentures over a 5-year follow-up period. MATERIALS AND METHODS: All subjects who had been advised and planned for two-implant mandibular overdenture treatment were included in this study. The peri-implant parameters -including plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) as well as marginal bone loss (MBL) - were assessed. In addition, prosthodontic parameters including abutment-, implant- and denture-related complications were assessed. Patients were evaluated at follow-up visits, scheduled at 1, 12, 24, 36, 48, and 60 months. The data distribution was analysed with the Shapiro-Wilk test. Data within follow-up categories were compared using ANOVA and the Tukey-Kramer test. A p-value < 0.05 was considered statistically significant. RESULTS: Among the 32 participants, 19 were males and 13 were females, with a mean age of 60.5 ± 7.33. The mean plaque index (PI), bleeding index (BI) and peri-implant pocket depth (PIPD) varied over time. However, no statistically significant difference was observed in the plaque index, bleeding index and peri-implant pocket depth over time (p > 0.05). The mean value at baseline was found to be -0.9 ± 0.3. The values increased over time, with the highest value observed at 60 months 2.6 ± 0.7, which was statistically significant (p < 0.001). CONCLUSION: Immediately placed and loaded mandibular implant overdentures using two un-splinted implants with locator attachments showed acceptable PI, BI and PIPD at the 5-year follow-up. Statistically significantly greater marginal bone loss was observed from baseline to follow-up, but it was within acceptable limits. A moderate number of restorative and abutment complications were observed during the follow-up of IODs.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Seguimentos , Revestimento de Dentadura , Resultado do Tratamento , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/etiologia , Mandíbula
12.
BMC Oral Health ; 24(1): 138, 2024 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-38281916

RESUMO

Different characteristics of bars (cross-sectional shape, diameter, distal extension etc.) lead to different biomechanical behavior (retention and stress) with implants and peri-implant tissues.Aim: To evaluate the impact of implant-supported removable prostheses bar designs in fully edentulous arch (in the maxilla and/or mandibula), with 4 implants or more, on the peri-implant soft and hard tissues.Two reviewers searched for observational studies, RCT and in vitro studies, published on five main databases and three from the grey literature, without restrictions on November 2023.Of the 3049 selected articles, four met the inclusion criteria. Four RCT evaluated peri-implant health tissues in full edentulous arches with 4 or 6 implants rehabilitated with implant bar overdentures. One prospective study with 5 years follow-up evaluated the success/survival rate of implants and implant bar overdentures. Overall, 261 subjects were enrolled in our systematic review with 1176 implants. Overdentures' survival rate was 100%. There was a trend that plaque indices and gingival indices were low in all of the studies, however no statistical analysis was done due to the lack of information.Due to the lack of information in the included studies, we cannot confirm if bar characteristics affect the peri-implant tissues health.


Assuntos
Implantes Dentários , Arcada Edêntula , Boca Edêntula , Humanos , Estudos Prospectivos , Prótese Dentária Fixada por Implante , Mandíbula , Revestimento de Dentadura , Retenção de Dentadura
13.
Compend Contin Educ Dent ; 45(2): 93-95, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38289627

RESUMO

Swallowed or aspirated dentures may result in serious systemic complications and require multidisciplinary attention or intervention. With an increasing number of edentulous elderly patients, such situations are not uncommon occurrences in everyday dentistry. In fact, dentures are the most ingested foreign body in the elderly patient population, and this is a particular risk if the dentures are lacking in stability. The present case report discusses the swallowing of an overdenture by a 95-year-old patient, who underwent endoscopic removal of the foreign body. The aim of this article is to highlight the risks of prosthetic restoration in older patients and the importance of thorough, scrupulous follow-up.


Assuntos
Corpos Estranhos , Boca Edêntula , Idoso de 80 Anos ou mais , Humanos , Deglutição , Revestimento de Dentadura , Corpos Estranhos/complicações , Corpos Estranhos/cirurgia
14.
Spec Care Dentist ; 44(1): 109-116, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-36872869

RESUMO

INTRODUCTION: Down syndrome (DS), an easily recognized congenital disease, is associated with a high prevalence of dental anomalies. Therefore, special dental care is required. CASE PRESENTATION: This case report described the minimally invasive prosthetic rehabilitation of a 31-year-old female patient with DS. Prompt diagnosis, consultation with physicians and family, and accurate medical history were needed, and relevant dental, medical, mental, and behavioral factors were considered. A minimally invasive treatment plan was decided after clinical examination, orthopantomography (OPG), and study model analysis. For the upper jaw, an over denture was constructed. For the lower jaw, a simple metal-frame partial denture was made. This treatment plan was decided after considering the difficulty in dentist-patient collaboration and a small maxilla with poor positioning of teeth and negative overbite and over jet. CONCLUSION: Considering different patient factors including patient cooperation, as well as the medical and dental conditions associated with DS, a minimally invasive prosthodontic treatment option was recommended.


Assuntos
Prótese Parcial Removível , Síndrome de Down , Feminino , Humanos , Adulto , Síndrome de Down/complicações , Maxila , Mandíbula , Revestimento de Dentadura , Prótese Dentária Fixada por Implante
15.
J Mech Behav Biomed Mater ; 150: 106269, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38043259

RESUMO

BACKGROUND: The stud-shaped attachment systems (AS) with different shape designs (ball, cylindrical, conical) and materials (metallic, plastic, or a combination of both) are commonly used to provide better retention and stability in implant-retained mandibular overdentures (IRMO). PURPOSE: The purpose of the present study was to evaluate and compare the retention loss and the wear (patterns, location, material loss) of three resilient unsplinted AS: a well-established ball attachment system (BAS) and two more recent cylindrical attachment systems (CAS), Locator R-Tx® and Novaloc®. MATERIALS AND METHODS: The implants, their corresponding abutments, the color-coded or position-coded retention devices (RD), the matrix metal housing were incorporated within CAD/CAM resin blocks and cyclically loaded with 19.6 N along the implant axis in a chewing machine to simulate 10,000 insertion-removal cycles (IRC). At cycle 10, 100, 1,000, 5,000, and 10,000, the retention force was measured using a universal testing machine. The wear was qualitatively examined using a binocular magnifier for both systems, and quantitatively assessed from micro-computed tomography acquisitions for CAS. Material loss exceeding 50 µm was considered significant. RESULTS: The three AS showed different retentive behavior along time. All the Locator R-Tx® RD lost more than 50 % of their retention after 10,000 IRC. The retention of the Ball System slightly varied over time, the final retention loss in Bmed and Bmax groups being lower than 25 % of the initial retention. Wear was located at the tip of their gold RD and at the equator area of their ball abutment. For Locator R-Tx®, the more retentive the plastic RD, the greater its wear and retention loss. Only Novaloc® maintained a stable retention with even a slight tendency to increase and showed a negligible wear. Implant abutments of the CAS showed no significant wear. CONCLUSION: After 10,000 IRC, corresponding to approximately 5-years clinical use, almost all RD provided retention force over 5 N, which could be sufficient to maintain satisfaction in most of the patients. The retention loss observed most prominently for the Locator R-Tx®, then for the Ball System, seemed to correlate with the wear observed on their RD. The practitioner may expect less RD maintenance with the Novaloc® stable retention overtime.


Assuntos
Implantes Dentários , Revestimento de Dentadura , Humanos , Retenção de Dentadura/métodos , Microtomografia por Raio-X , Mandíbula , Análise do Estresse Dentário
16.
Clin Exp Dent Res ; 10(1): e813, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38044541

RESUMO

OBJECTIVES: This study sought to determine the impact of age, gender, and use of maxillary implant-supported overdenture (UISOD) versus conventional denture (CMD) opposing mandibular implant-supported overdenture (LISOD) and the number of years the patient has used their prosthesis on the ratings of satisfaction. This study aimed to assess the long-term influence of different factors on patients' satisfaction with LISODs needing a maxillary prosthesis, helping dentists choose a treatment pathway that leads to a higher satisfaction rate. MATERIAL AND METHODS: This cross-sectional study included 84 participants. They were treated with LISOD opposing either CMD or UISOD from 2015 to 2020. They were all eligible to participate in the study. An oral health impact profile (OHIP-14) questionnaire was given to each patient and filled out by them. OHIP-14 scores were gathered and went under statistical analysis with PASS-11 software to determine the relationship between patients' satisfaction with the scores. RESULTS: Age and gender had no significant influence on how satisfied patients were. Patients with maxillary overdentures showed more satisfaction than the CMD group (p < .05). Moreover, patients' satisfaction decreased with increasing years of prostheses usage (p < .05). CONCLUSIONS: This study demonstrated that satisfaction is related to the type of maxillary prosthesis (conventional or implant-supported) used opposing LISODs and the number of years the patient had used the prostheses.


Assuntos
Implantes Dentários , Satisfação do Paciente , Humanos , Revestimento de Dentadura , Estudos Transversais , Retenção de Dentadura , Prótese Dentária Fixada por Implante
17.
Clin Implant Dent Relat Res ; 26(1): 103-112, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37926953

RESUMO

OBJECTIVES: This study aimed to evaluate the clinical outcomes and patient satisfaction of 4-implant-assisted maxillary overdentures using two different designs. MATERIALS AND METHODS: Thirty edentulous participants received four implants in the maxillary ridge. The patients were randomly divided into two equal groups: (1) the control (CG, Vertical) group (n = 15); participants received four vertical implants with straight locator attachments to retain maxillary overdentures, and (2) the study (SG, Angled) group (n = 15); participants received four angled implants with angled locator attachments to retain maxillary overdentures. Peri-implant tissue health [Plaque (PL) and gingival (GI) indices, pocket depth (PD), implant stability (ISQ) and crestal bone loss (CBL)] were evaluated after denture insertion (T0), 6 (T6), and 12 (T12) months after insertion. Patient satisfaction was evaluated using a visual analog scale (VAS) after 12 months. RESULTS: The survival rates were 96.7% and 95% for the control and study groups respectively. PL, GI, and PD increased significantly in both groups with the passage of time. No significant difference in PL, GI, PD, and ISQ was noted between groups at all observation times. CG showed higher CBL than SG at T12. For the VAS results, there was no significant difference between groups. SG recorded significantly higher satisfaction regarding comfort with maxillary and mandibular dentures, retention of mandibular dentures, oral hygiene, the ability to chew hard food, and occlusion than CG. CONCLUSION: Within the limitations of this study, angled implants with angled locator attachments may be recommended to retain maxillary overdentures opposing intact dentition or fixed restoration as it was associated with improvements of several parameters of peri-implant tissue health and patient satisfaction compared to vertical implants with straight locator attachments.


Assuntos
Implantes Dentários , Placa Dentária , Arcada Edêntula , Humanos , Revestimento de Dentadura , Retenção de Dentadura/métodos , Satisfação do Paciente , Mandíbula , Prótese Dentária Fixada por Implante
18.
J Prosthodont ; 33(2): 164-170, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36779671

RESUMO

PURPOSE: To investigate the retentive behavior of the Locator legacy and Novaloc attachment systems with different retention inserts both within and across systems under cyclic load. MATERIALS AND METHODS: Three retention inserts of each system (green, yellow, and white for Novaloc; green, orange, and red inserts for extended range for legacy Locator) were tested on abutments of both systems with a sample number of 10 per force and 10,000 cycles of insertion and removal. The loading was applied in the axial direction of the abutments, which were placed in artificial saliva. The retention force was measured in each cycle. The results were compared with the manufacturer's specifications and evaluated for a simulated period of use of 10 years. Characteristic time constants were determined, and subsequently, the two systems were compared regarding their wear behavior. RESULTS: The manufacturer's specifications could only be confirmed for the green Novaloc retention insert on a Novaloc abutment (t-test: p = 0.50); for all other inserts, the baseline exceeded the manufacturer's specifications by 30%-75% (Novaloc; t-test: p < 0.001) and 75%-550% (Locator; t-test: p < 0.001). After 10,000 cycles performed, the manufacturer's specifications were confirmed on a Novaloc abutment for the white Novaloc retention insert (t-test: p = 0.86) and on a Locator abutment for the green Novaloc retention insert (t-test: p = 0.32). Both systems lost retention force during the experiment. Overall, Novaloc inserts on both abutments showed less wear (decrease to 56%-85% of initial force) and a slower decrease in retention force compared to Locator inserts (decrease to 6%-31% of initial force). CONCLUSIONS: In both systems, wear leads to a varying loss of retention; therefore, regular checks with possible replacement of the inserts are necessary in clinical use. Novaloc attachments seem to be more resistant to the loss of retention than Locator attachments. A cross-combination may be clinically useful in some cases.


Assuntos
Implantes Dentários , Retenção de Dentadura , Retenção de Dentadura/métodos , Revestimento de Dentadura , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário , Saliva Artificial
19.
J Prosthet Dent ; 131(2): 281.e1-281.e9, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37985307

RESUMO

STATEMENT OF PROBLEM: The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with mandibular edentulism. However, information on the influence of implant positions on crestal strain is lacking. PURPOSE: The purpose of this in vitro study was to evaluate the crestal strain around 2 implants to support mandibular overdentures when placed at different positions. MATERIAL AND METHODS: Edentulous mandibles were 3-dimensionally (3D) designed separately with 2 holes for implant placement at similar distances of 5, 10, 15, and 20 mm from the midline, resulting in 4 study conditions. The complete denture models were 3D designed and printed from digital imaging and communications in medicine (DICOM) images after scanning the patient's denture. Two 4.3×12-mm dummy implants were placed in the preplanned holes. Two linear strain gauges were attached on the crest of the mesial and distal side of each implant (CH1, CH2, CH3, and CH4) and connected to a computer to record the electrical signals. Male LOCATOR attachments were attached, the mucosal layer simulated, and the denture picked up with pink female nylon caps. A unilateral and bilateral force of 100 N was maintained for 10 seconds for each model in a universal testing machine while recording the maximum strains in the DCS-100A KYOWA computer software program. Data were analyzed by using 1-way analysis of variance, the Tukey post hoc test, and the paired t test (α=.05). RESULTS: Under bilateral loading, the strain values indicated a trend with increasing distance between the implants with both right and left distal strain gauges (CH4 and CH1). The negative (-ve) values indicated the compressive force, and the positive (+ve) values indicated the tensile force being applied on the strain gauges. The strain values for CH4 ranged between -166.08 for the 5-mm and -251.58 for the 20-mm position; and for CH1 between -168.08 for the 5-mm and -297.83 for the 20-mm position. The remaining 2 mesial strain gauges for all 4 implant positions remained lower than for CH4 and CH1. Under unilateral-right loading, only the right-side distal strain gauge CH4 indicated the increasing trend in the strain values with -147.5 for the 5-mm, -157.17 for the 10-mm, -209.33 for the 15-mm, and -234.75 for the 20 mm position. The remaining 3 strain gauges CH3, CH2, and CH1 ranged between -28.33 and -107.17. For each position for both implants, significantly higher (P<.05) strain values were observed on the distal strain gauge channels CH4 and CH1 than on the mesial channels CH3 and CH2 under bilateral loading and on the right side under unilateral loading. CONCLUSIONS: Peri-implant crestal strains in the 2IMO increased by increasing the distance of the implants from the midline. The stress values progressively increased from 5 to 10 mm to 15 to 20 mm from midline, represented as lateral incisor, canine, and premolar positions. The distal side of the implants exhibits higher strains than the mesial side of the implants.


Assuntos
Implantes Dentários , Humanos , Feminino , Masculino , Revestimento de Dentadura , Prótese Dentária Fixada por Implante , Análise do Estresse Dentário/métodos , Mandíbula/cirurgia , Impressão Tridimensional , Retenção de Dentadura
20.
Dent Mater J ; 43(1): 90-96, 2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38148022

RESUMO

This study aimed to evaluate the thermocycling effect on the retentive force of 3 different retentive inserts in 3 denture attachments (Blue, Pink, Clear retentive inserts in LOCATOR; Blue, Pink, Clear retentive inserts in LOCATOR R-Tx; and White, Yellow, Green retentive inserts in Novaloc) (n=10). Maximum retentive force of each retentive insert was evaluated at baseline, 7-day water storage, and after 5,000-, and 10,000- cycle thermocycling. The water absorption percentage of the retentive inserts was also determined. Comparing between baseline and 7-day water storage, the retentive forces of the LOCATOR and LOCATOR R-Tx groups were significantly reduced (p<0.05), while the retentive force of the Novaloc group was significantly increased (p<0.05). Comparing between 7-day water storage and 10,000-cycle thermocycling, the retentive force of most retentive inserts remained unchanged (p>0.05). The water absorption percentage of the LOCATOR and LOCATOR R-Tx groups was significantly greater than that of the Novaloc group (p<0.05).


Assuntos
Retenção de Dentadura , Água , Revestimento de Dentadura , Análise do Estresse Dentário , Prótese Dentária Fixada por Implante
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...